Calibration System

Sensor Calibration System SCS-XXX

  • Force, Accelerometer, Displacement, Pressure, Angular Rate, Voltage, Current Sensor Calibration System;
  • According to JJF, GB/T, ISO, SAE, etc. Regulation;
  • Static Calibration;
  • Calibration Range by Required;
  • Calibration Fixture Supplied;
  • Calibration Parameters by Required.
SCS-XXX serials calibration system mainly focus on vehicle safety test field, including dummy loadcell, seatbelt loadcell, pedestrian protection leg form loadcell, dummy and vehicle body accelerometers, kinds of displacement (as IR-TRACC), Gyro, door pressure sensor, airbag pressure sensor, airbag squib current sensors, and EV/HEV high voltage and current sensor. These calibration systems are suitable to the sensors of general industry.

Specification (Force Calibration System SCS-FO):
Name Unit Value
Range kN ≤45
Loading Method / Step/Continues
Cal. Index Sensitivity, offset, Non-Linearity, Hysteresis, Crosstalk, Shunt.
Excitation V 2.5/3.3/5/10
Seatbelt Loadcell Cal. ISO 17242 Support
Sensor Test Chain Amp≤10V Support
 
Specification (Accelerometer Calibration System SCS-AC):
Name Unit Value
Amp. Cal. Range g 25~2000
Freq. Cal. Range Hz 20~5000
Regulation ISO16063 GB/T20485
Cal. Index Sensitivity, Deviation, Offset
Excitation for PR V 5/10
Excitation for IEPE mA 4
PE Accelerometer pC input Support
Sensor with Test Chain Amp≤10V Support
 
Specification (Displacement Calibration System SCS-DS):
Name Unit Value
Cal. Range mm <2000
Cal. Objects H3/ES2/WS/THRO/Q Serial Dummy Rib Displacement, Knee Pot. and Other String Pot
Cal. Index Sensitivity, Non-Linearity
Specification (Pressure Calibration System SCS-PR):
Name Unit Value
Cal. Range kPa ≤600
Loading Method Static JJF1640-2017
Cal. Index Sensitivity. Offset. Non-Lin. Hys.
Excitation V 5/10
 
Specification (Angular Rate Calibration System SCS-AV):
Name Unit Value
Cal. Range deg/s ≤15000
Loading Method Static JJF1535-2015
Cal. Index Sensitivity. Offset. Non-Lin. Hys.
Excitation V 5/10
 
Specification (Voltage Calibration System SCS-VO):
Name Unit Value
Cal. Range V ≤1000
Loading Method Static DAQ by Step
Cal. Index Sensitivity. Offset. Non-Lin. Hys.
Excitation V 5/10
3-Ch Voltage Sensor Optional for EV/HEV V1,V2,Vb
 
Specification (Current Calibration System SCS-CU):
Name Unit Value
Cal. Range A ≤2500
Cal. Index Sensitivity. Offset. Non-Lin. Hys.
Excitation/Power Supply V 5/10/±15/24
 
Note: Ampere-turn Method applied Above 100A.

Sensor Calibration System SCS-XXX