Force, Accelerometer, Displacement, Pressure, Angular Rate, Voltage, Current Sensor Calibration System;
-
According to JJF, GB/T, ISO, SAE, etc. Regulation;
-
Static Calibration;
-
Calibration Range by Required;
-
Calibration Fixture Supplied;
-
Calibration Parameters by Required.
SCS-XXX serials calibration system mainly focus on vehicle safety test field, including dummy loadcell, seatbelt loadcell, pedestrian protection leg form loadcell, dummy and vehicle body accelerometers, kinds of displacement (as IR-TRACC), Gyro, door pressure sensor, airbag pressure sensor, airbag squib current sensors, and EV/HEV high voltage and current sensor. These calibration systems are suitable to the sensors of general industry.
Specification (Force Calibration System SCS-FO):
Name |
Unit |
Value |
Range |
kN |
≤45 |
Loading Method |
/ |
Step/Continues |
Cal. Index |
Sensitivity, offset, Non-Linearity, Hysteresis, Crosstalk, Shunt. |
Excitation |
V |
2.5/3.3/5/10 |
Seatbelt Loadcell Cal. |
ISO 17242 |
Support |
Sensor Test Chain |
Amp≤10V |
Support |
Specification (Accelerometer Calibration System SCS-AC):
Name |
Unit |
Value |
Amp. Cal. Range |
g |
25~2000 |
Freq. Cal. Range |
Hz |
20~5000 |
Regulation |
ISO16063 |
GB/T20485 |
Cal. Index |
Sensitivity, Deviation, Offset |
Excitation for PR |
V |
5/10 |
Excitation for IEPE |
mA |
4 |
PE Accelerometer |
pC input |
Support |
Sensor with Test Chain |
Amp≤10V |
Support |
Specification (Displacement Calibration System SCS-DS):
Name |
Unit |
Value |
Cal. Range |
mm |
<2000 |
Cal. Objects |
H3/ES2/WS/THRO/Q Serial Dummy Rib Displacement, Knee Pot. and Other String Pot |
Cal. Index |
Sensitivity, Non-Linearity |
Specification (Pressure Calibration System SCS-PR):
Name |
Unit |
Value |
Cal. Range |
kPa |
≤600 |
Loading Method |
Static |
JJF1640-2017 |
Cal. Index |
Sensitivity. Offset. Non-Lin. Hys. |
Excitation |
V |
5/10 |
Specification (Angular Rate Calibration System SCS-AV):
Name |
Unit |
Value |
Cal. Range |
deg/s |
≤15000 |
Loading Method |
Static |
JJF1535-2015 |
Cal. Index |
Sensitivity. Offset. Non-Lin. Hys. |
Excitation |
V |
5/10 |
Specification (Voltage Calibration System SCS-VO):
Name |
Unit |
Value |
Cal. Range |
V |
≤1000 |
Loading Method |
Static |
DAQ by Step |
Cal. Index |
Sensitivity. Offset. Non-Lin. Hys. |
Excitation |
V |
5/10 |
3-Ch Voltage Sensor |
Optional for EV/HEV V1,V2,Vb |
Specification (Current Calibration System SCS-CU):
Name |
Unit |
Value |
Cal. Range |
A |
≤2500 |
Cal. Index |
Sensitivity. Offset. Non-Lin. Hys. |
Excitation/Power Supply |
V |
5/10/±15/24 |
Note: Ampere-turn Method applied Above 100A.