Equipment

Onboard Battery BAT-48V

  • Applied to 48VDC power supply requirement, the interface can be customized;
  • Max. Output Current 10A;
  • Anti-Shock design;
  • Built-in UPS automatic bypass function;
  • Built-in battery charge management;
  • Over current and over temperature protection.
Onboard battery BAT-48V, selects power lithium battery cell design, is about 54V when fully charged, and a discharge cut-off voltage of 24V. Built-in UPS automatic bypass circuit, when the external power supply is greater than 36V (default value, the threshold can be customized), it will automatically switch to the external power supply; the maximum battery charging current is 1.2A, and the maximum input voltage of the external power supply is 54V. The connector can be defined by customer, and JBUS DAS bus is as default.

Specification (25℃)
Name Unit Value
Capacity Wh 120
Rated Voltage V 48
Charge Full voltage V 54
Discharge Cut-off V 36
UPS Switch V 24(default)
Charge Min Voltage V 30(default)
Max. External Voltage V 54
Max. Output Current A 10
Max. Charge Current A 1.2
Power Display LED 5-STEP
Anti-Shock (XYZ) >100g @6ms half sine
Material / Al. Alloy
Weight kg 2.7
Dimension mm 230×64×98
Battery Capacity Remaining Indicator:

Connector Define (JBUS as default)
Battery Input & Output FGG.EGG.2B.316


Pin 1,11,12 Power+
Pin 2,3,13 Power-
Pin 4, 5, 6, 14 Ethernet Bus
Pin 7, 8 T0 Diff. Trigger
Pin 15, 16 SR Diff. Trigger
Pin 9 Trigger GND
Pin 10 Trigger Termination
 
Dimension:


Onboard Battery BAT-48V