Suitable to hydrogen concentration measurement;
- Measurement precision 0.1%VOL;
- T90 response time≤10sec;
- Easy mounting;
- Anti-Shock >100g, support HFCV crash test;
- Analog voltage output and RS485 are optional.
The hydrogen sensor is based on the principle of catalytic combustion to detect the concentration of hydrogen in the air. The front end of the sensor uses a chip prepared by the MEMS micro-hot plate process that meets the vehicle standard, and obtains a stable and reliable signal through temperature compensation and signal filtering and amplification. The sensor is supplied with high-performance wear-resistant cables, custom lengths, Dallas IDs and connectors.
Specification(with 10V excitation, 25℃):Name | Unit | Value |
Test range | %vol | 5 |
Test error | %vol | ≤±0.1 |
Non-Linearity | %FS | ≤±1.5 |
Signal output | V | 0.5~4.5 |
Excitation Voltage | V | 8~16 |
Current | mA | 60 |
T90 response time | sec | ≤10 |
Operational Temp. | ℃ | -10~40 |
Anti-Shock | g | ≥100 |
Insulation Res. | MΩ | ≥100 |
Mounting | / | 4×M4 |
Case material | / | Nylon |
Mass | grams | 80 |
Dimension | mm | 70×60×35 |
Note: Sensor Type is Active Sensor with Excitation;
The cable length is 8m;
No connector and no Dallas ID as default.
Dimension:
Wires Define:
Red | Excitation voltage+ |
Black | Excitation voltage- |
White | Signal- |
Green | Signal+ |
Shield | Connector Case |
![]() |
Hydrogen Sensor H2-5B |